Vibration velocity transducer AV04

Purpose:
  • Measuring vibration velocity in stationary vibrodiagnostic systems according to GOST ISO 10816 and GOST ISO 2954.
Features:
  • The built-in electronic amplifier-transducer converts the piezoelement signal to a low-resistance voltage signal proportional to vibration velocity.
  • Electric insulation of piezoelement and built-in amplifier-transducer from the body eliminates the influence of grounding loop currents on measurement results.
  • Robust design, waterproof casing and non-detachable armored cable.
  • Stable characteristics and reliable operation.
Check price with the manufacturer
Description
Documents
  • Parameter
    Value
  • Conversion factor
    4,4 ± 0,44 mV/mm/s
  • Relative coefficient of transverse conversion (less than)
    0,05
  • Operating frequency range
    2 ... 3000 Hz
  • Max. shock limit (peak value)
    500 g
  • DC voltage level at the output
    10 ... 23 V
  • Power supply
    18 ... 30 V
  • 0,1 ... 8 mA
  • Vibration velocity measuring range
    0,1 ... 500 mm/s
  • 0,05 mm/s
  • Maximum output voltage at nonlinear distortion factor not greater than 5 %
    ±5 V
  • Operating temperature range
    -50 ... 125 °C
  • 0,1 %/°С
  • Connector type
    4*the tip of the fur. Clip
  • Built-in cable
    2 m
  • Output direction
    horizontal
Electric Circuit of AV04
SUBMIT A REQUEST
I have read and accept the privacy policy
SUBMIT A REQUEST
[contact-form-7 404 "Not Found"]
Get price
I have read and accept the privacy policy
Get production catalog