Vibration transducer AP2035-100-01

Purpose:
  • Measuring vibration and shock acceleration in diagnostic systems and laboratory tests under strong electromagnetic fields.
Features:
  • Built-in preamplifier.
  • Electrically insulated piezoelement and built-in preamplifier.
  • High axial sensitivity, self-resonant frequency and shock resistance.
  • Low sensitivity to electromagnetic fields.
  • Wide range of power supply voltage and current.
  • Low level of intrinsic noise.
  • Explosion-proof version 1ExibIICT4 (optional).
Check price with the manufacturer
Description
  • Parameter
    Value
  • Conversion factor
    10 mV/m/s²
  • Relative coefficient of transverse conversion (less than)
    0,05
  • Operating frequency range
    0,5 ... 8000 Hz
  • Maximum amplitude value of the measured parameter
    500 m·s²
  • Max. shock limit (peak value)
    1000 g
  • Adjustment resonance frequency in axial direction (higher than)
    25 кHz
  • Noise level, RMS [1 Hz ÷ 10 kHz ] (less than)
    0,002 m/s²
  • Output resistance less than
    500 Оm
  • DC voltage level at the output
    8 ... 13 V
  • Power supply
    18 ... 30 V
  • 2 ... 20 mA
  • Operating temperature range
    -55 ... 125 °C
  • 0,2 %/°С
  • Connector type
    cable output, 2РМД18КПN4Г5V1
  • Built-in cable
    2 m
  • Output direction
    horizontal