Vibration transducer AP2022-2-02

Purpose:
  • Measuring vibration and shock acceleration in diagnostic systems and laboratory tests under strong electromagnetic fields.
Features:
  • High axial sensitivity, self-resonant frequency and shock resistance.
  • Low sensitivity to electromagnetic fields.
  • Built-in preamplifier.
  • Wide range of power supply voltage and current.
  • Low level of intrinsic noise.
Check price with the manufacturer
Description
Documents
  • Parameter
    Value
  • Conversion factor
    0,2 mV/m/s²
  • Relative coefficient of transverse conversion (less than)
    0,05
  • Operating frequency range
    10 ... 20000 Hz
  • Maximum amplitude value of the measured parameter
    25000 m·s²
  • Max. shock limit (peak value)
    5000 g
  • Adjustment resonance frequency in axial direction (higher than)
    60 кHz
  • Noise level, RMS [1 Hz ÷ 10 kHz ] (less than)
    0,01 m/s²
  • Output resistance less than
    500 Оm
  • DC voltage level at the output
    10 ... 13 V
  • Power supply
    18 ... 30 V
  • 2 ... 20 mA
  • Run mode setting time
    4 c
  • Operating temperature range
    -55 ... 125 °C
  • 0,2 %/°С
  • Connector type
    LEMO FGG.1B.308; -01 - 3*BNC; -02 - 2РМ14Б4Ш1V1; -03 - 2РМ14КПN4Г1AV
  • Built-in cable
    2 m
  • Output direction
    horizontal
Electric Circuit of AP2022-2-02
SUBMIT A REQUEST
I have read and accept the privacy policy
SUBMIT A REQUEST
[contact-form-7 404 "Not Found"]
Get price
I have read and accept the privacy policy
Get production catalog