Amplifier AP5110

Purpose:
  • Conversion and measurement of RMS of signals from piezoelectric transducers in the modes:
  • charge amplifier (connecting transducers with charge output);
  • voltage amplifier (connecting transducers with built-in electronics).
Features:
  • Modular structure.
  • Metal casing.
  • Balanced and unbalanced input of charge amplifier.
  • Input signal integration.
  • Normalization mode.
  • Overload indication.
  • Low level of noise.
  • Built-in voltmeter that measures RMS of an output signal.
  • Interface for connecting to computer USB.
  • Measurement report.
Check price with the manufacturer
Description
Documents
  • Parameter
    Value
  • Maximum input charge (peak value)
    ± 100000 pC
  • Maximum input voltage (peak value)
    ± 10 V
  • Conversion factor for charge (corresponds to a series of 1, 2, 5)
  • Conversion factor for voltage (corresponds to a series of 1, 2, 5)
  • Normalization range (increment 0.01) of conversion factor
  • Limits of basic relative error of conversion factor setting at 200 Hz
    ± 0,8 %
  • ± 1,6 %
  • Maximum output voltage (peak value) at nonlinear distortion factor < 5%, not lower than
    ± 10 V
  • Operating frequency range with attenuation on the boundaries -10 %
    0,2 (at the level minus 30 %) ... 100000 Hz (at minus 10 %)
  • 2 … 2000 Hz
  • Frequency-response ripple
    ± 0,5 %
  • ± 2,0 %
  • Input resistance (higher than)
    1000000 кОm
  • Output resistance (not higher than)
    100 Оm
  • Acceptable additional relative error limits of conversion factor for charge in the operating temperature range 0 to 50 °C
  • Cutoff frequencies of built-in high pass filters (increment 0.1; 1; 10; 100 Hz) with decline in frequency response not less than 40dB/decade and attenuation -10 %
    from 0, 2 to 200 Hz (ФVЧ на чаstfromе sреза 0,2 Hz иmееt заtухание не более 30 %)
  • from 2 to 200 Hz
  • Cutoff frequencies of built-in low pass filters (increment 0.1; 1; 10; 10 kHz) with decline in frequency response not less than 40dB/decade and attenuation -10 %
    from 0,1 to 100 кHz
  • 1; 2 кHz
  • Basic relative error limits for RMS value of the output signal voltage in the range from 100 mV to the maximum and within frequencies from 20 to 100 000 Hz
    ± 1 %
  • 700 mA
  • Powering mode of sensors
    + (22 ± 2) V
  • from 3 to 15 mA (To be determined by customer)
  • Root mean square (RMS) value of noise reduced to the input, in the mode of voltage conversion in the frequency range from 3 Hz to 30 kHz (maximum)
    20 µV
  • Root mean square (RMS) value of noise reduced to the input, in the mode of charge conversion for sensor capacity 1 nF in the frequency range from 3 Hz to 30 kHz (not higher than)
    0,02 pC
  • Power supply
    self-contained power supply, mains supply from adapter
  • Connector type
    input / output
  • Delivery set
    The amplifier of the measuring AP5110; Passport; operator's Manual; shielding Plug; Installation CD-ROM program AP5110 Explorer; USB Cable A-B; user Manual; power Unit AS05-01 (~220 V/=12 V, >= 1 A ) ; cable Plug TWIN BNC; Capacitive transducer E1000