Ru
Information
About company
Career
Documents
Publications
For investors
News
Production
Sensors
Vibration transducer
Vibration velocity transducer
Vibration switch
Force sensor
Dynamic pressure sensor
The Converter of acoustic emission
Acoustic emission sensor
Impulse hammer
Pad with three-axis vibration transducer
Eddy-current sensor
Calibrators
Amplifiers
Amplifier module
Chassis casing
ADMV
BRHV
Electric auxiliary units
Matching device
Electrical equivalent
Power unit
Programming panel
Measuring instruments
Instrument set
Vibrometer
Analyzer
Vibration controller
Simulation workbench
Ballistic facility
Optional accessories
Cable adapter
Thread adapter
Seal ring
Spacers
Cable connector
Cable connector accessories
Stud
Magnet mounting base
Probe
Wax mastic
Mounting block
Mounting device
Impulse hammer accessories
Vibration adapter
Filter
Warranty
Opinions
Make order
Operation guidelines
Wiring diagrams
Metrology
Partners
Dealers & representatives
Exhibitions
Contacts
Contacts
Employees
Company card
Basket
+7 (831-30) 6-77-77
0
No products in the cart.
Home
/
Amplifiers
/
Amplifier
/
Charge and voltage
/ Amplifier AP5030-4
Amplifier AP5030-4
Purpose:
Vibration (vibroacceleration) measurements in the modes:
charge amplifier;
voltage amplifier.
Features:
Vibroacceleration measurements.
Normalization mode.
Overload indication.
Low level of noise.
Control and power supply via USB.
Check price with the manufacturer
Количество
Add to cart
Description
Parameter
Value
Maximum input charge (peak value)
± 5 · 104 pC
Maximum input voltage (peak value)
± 5 V
Conversion factor for charge (corresponds to a series of 1, 2, 5)
Conversion factor for voltage (corresponds to a series of 1, 2, 5)
Normalization range (increment 0.01) of conversion factor
Limits of basic relative error of conversion factor setting, not greater than
± 0,8 %
Maximum output voltage (peak value) at nonlinear distortion factor < 5%, not lower than
± 5 V
RMS value of intrinsic noise reduced to the input, for sensor capacity 1 nF (not higher)
20 · 10-3 pC
Current consumption (maximum)
400 mA
Input resistance (higher than)
1011 Оm
Output resistance (not higher than)
100 Оm
Acceptable additional relative error limits of conversion factor for charge in the operating temperature range 0 to 50 °C
Operating frequency range with attenuation on the boundaries -30%
from 0,2 to 120 000 Hz
Cutoff frequencies of built-in high pass filters (increment 0.1; 1; 10; 100 Hz) with decline in frequency response not less than 40dB/decade and attenuation -10 %
from 0,3 to 200 Hz (ФVЧ на чаstfromе sреза 0,2 Hz иmееt заtухание не более 30%)
Cutoff frequencies of built-in low pass filters (increment 0.1; 1; 10; 10 kHz) with decline in frequency response not less than 40dB/decade and attenuation -10 %
from 0,1 to 100 Hz
+ (5 ± 0,5) V
Powering mode of sensors
+ (24 ± 2) V
3 … 15 mA (To be determined by customer)
Root mean square (RMS) value of noise reduced to the output, in the mode of voltage conversion (not higher than)
20 µV
Root mean square (RMS) value of noise reduced to the output, in the mode of charge conversion for capacitance 1 nF (not higher than)
0,02 pC
Power supply
mains supply from power unit AS05-03, USB from computer
Connector type
input / output
Overall dimensions
157 x 236 x 75 mm
Weight
1500 g
Delivery set
CD CD AP5030-4 Explorer; USB cable A-B; a power supply unit ~220V/+5V, ±0.5 A capacitive transducer E1000